Attested HPE0-S59 Dumps PDF Resource [2023]
Latest HPE0-S59 Actual Free Exam Questions Updated 60 Questions
HP HPE0-S59 (HPE Compute Solutions) Certification Exam is a valuable certification for professionals who want to demonstrate their expertise in HPE compute solutions. With a variety of training resources available and a globally recognized certification upon completion, HPE0-S59 exam is an excellent choice for those looking to advance their careers in the field of HPE compute solutions.
HP HPE0-S59 (HPE Compute Solutions) exam is a certification exam that validates the knowledge and skills of IT professionals in deploying, configuring, and managing HPE compute solutions. HPE0-S59 exam is designed for IT professionals who are involved in implementing and managing HPE server and storage solutions in complex environments. HPE0-S59 exam is ideal for individuals who are responsible for designing, deploying, and supporting HPE compute solutions for small, medium, and large enterprises.
NEW QUESTION # 31
Which statement about HPE Superdome Flex 280 is true?
- A. It can support up to two nPars with an external RMC.
- B. It must be equipped with at least 768 GB of memory.
- C. it cannot be managed using HPE OneView.
- D. It supports 2 to 8 sockets in 2-socket increments.
Answer: B
NEW QUESTION # 32
Your customer plans to setup an HPE Synergy solution based on SY480 Gen10 compute nodes with the following connectivity options - SAS connectivity installed in the first fabric - FC connectivity Installed In the second fabric - Ethernet connectivity installed in the third fabric.
Which statement regarding this setup is true?
- A. Each compute node must have at least 768GB of memory installed
- B. Compute nodes must have a second CPU installed to access the second fabric.
- C. Each interconnect module in each fabric must be properly licensed in HPE OneView
- D. Interconnect modules that provide SAS connectivity should be moved to the third fabric
Answer: A
NEW QUESTION # 33
Your customer wants to add dedicated Fibre Channel connectivity to the HPE Synergy frame running HPE Synergy 480 Gen10 compute modules, each with one CPU socket populated Currently they use two 12 Gb SAS switches and two HPE Virtual Connect SE 100Gb F32 Modules for HPE Synergy installed in third fabric.
What must be done to enable dedicated FC connectivity for this HPE Synergy frame?
- A. For VC-FC modules, all of server facing ports must be property licensed.
- B. SAS switches must be moved to second fabric and FC modules Installed in the first one.
- C. A second CPU must be installed for all HPE Synergy 480 Gen10 compute nodes.
- D. For Brocade switches, a logical interconnect group must be created in HPE OneView.
Answer: B
NEW QUESTION # 34
Your customer plans to deploy a VMware ESXi with HPE Synergy platform. They also plan a vSAN deployment leveraging HPE D3940 Storage Modules and SSD drives The customer requested the following components:
- HPE Synergy frame with ten HPE Synergy 480 Gen10 Plus compute modules
- Two HPE Virtual Connect SE 100Gb F32 Modules for Synergy
- An appropriate number of vSAN Standard licenses for each compute node
- One HPE O3940 Storage Module with 40 SSDs - All required cables and options Which statement about this request is true?
- A. vSphere licenses should be added, as vSAN licenses do not replace vSphere licenses
- B. 20 SSD drives should be removed from this setup, as D3940 supports only 20 SSD or SAS drives.
- C. vSphere Standard licenses should be replaced with Enterprise Plus licenses to enable vSAN
- D. One HPE Virtual Connect SE 100Gb F32 Module for Synergy should be replaced with 50GD/S ILM
Answer: C
NEW QUESTION # 35
Which statement about HPE Apollo 2000 Gen10 Plus platform is true?
- A. It can support a single processor only and up to 4 per chassis
- B. It is fully managed using HPE OneView including all connections
- C. It offers servers with AMD EPYC and Intel Xeon Scalable CPUs
- D. It is equipped with HPE Persistent memory by default
Answer: A
NEW QUESTION # 36
What is a restriction of using a RoCE network?
- A. it is not supported with HPE Virtual Connect SE 40 GD F8 Module for HPE Synergy.
- B. It does not support smart link and private network features.
- C. It is by default configured as an untagged network and cannot be a part of a network set.
- D. It does not support Private VLAN and Multicast VLAN.
Answer: C
NEW QUESTION # 37
An administrator tries to open iLO interlace from HPE OneView Instead of being automatically logged in a login prompt displays Where should you start the troubleshooting process?
- A. At the iLO interface to verify whether the SSO certificate is removed from an iLO.
- B. At HPE OneView Interface to verify whether the server is In the maintenance mode
- C. At the iLO interface to verify whether the ILO Advanced license is properly applied
- D. At HPE OneView Interface to verify whether the iLO processor is disabled
Answer: C
NEW QUESTION # 38
Your customer experienced some problems caused by outdated HPE Superdome Flex firmware. Which update method should they use to avoid these issues in the future?
- A. HPE OneView IT HPE Persistent Memory firmware must be updated.
- B. HPE SUM if HPE Persistent Memory firmware must be updated
- C. RMC CLI to update I/O and HPE Persistent Memory firmware
- D. HPE OneView method for I/O firmware update procedure
Answer: C
NEW QUESTION # 39
Which statement about the HPE D3940 storage module is true?
- A. Only one type of drives (SATA, SAS, SSD) can be installed in each module
- B. it is configured through CLl available from HPE Synergy console
- C. Up to five modules can be installed in a single frame with Gen10 servers
- D. SATA drives requires redundant 10 adapters to be installed in this module
Answer: B
NEW QUESTION # 40
Your customer plans to deploy VMware ESXi 7. 0 U2, and they are looking for a hardware platform that will allow them to use up to 16 CPU sockets Which HPE compute system meets the customer requirements?
- A. HPE ProLiant DL580 Gen10
- B. HPE ProLiant OL380 Gen 10 Plus
- C. HPE Synergy 480 Gen10 Plus
- D. HPE Superdome Flex system
Answer: C
NEW QUESTION # 41
Your customer has an HPE Synergy platform deployed and managed using HPE OneView. The customer also has HPE Superdome Flex with RMC deployed They plan to deploy a second nPar and HPE Superdome Flex
280 They plan to manage new components using HPE OneView
What must be done to achieve this goal?
- A. The customer has to add HPE Superdome Flex to the HPE OneView used to manage HPE Synergy
- B. The customer should deploy an HPE OneView appliance for HPE Superdome Flex management
- C. The customer must add a second Rack Management Controller for HPE Superdome Flex 280
- D. The customer must use IL05 to add HPE Superdome Flex systems to HPE OneView
Answer: C
NEW QUESTION # 42
Your customer has the following HPE Synergy setup
- 3 HPE Synergy 12000 Frames
- 4 HPE Virtual Connect SE 100 Gb F32 Modules
- 2 HPE Synergy 50 GO Interconnect Link Modules
- 36 HPE Synergy 480 Gen10 Plus compute modules
- 2 HPE Composer 2 modules
Which statement about this setup is true?
- A. To manage all frames, the customer must buy two additional HPE Composer 2 modules
- B. The customer can add one D3940 storage Module to each of the frames
- C. To use all compute nodes, the customer must create at least two logical enclosures
- D. The customer must buy 36 HPE OneView Advanced licenses to manage compute modules
Answer: D
NEW QUESTION # 43
You plan to configure a Link Aggregation Group (LAG) for two connections within a server profile for a compute node running an ESXI system.
What is required from the VMware side to enable LAG?
- A. Dedicated VMKernel port
- B. vSphere Standard license
- C. Virtual Distributed Switch
- D. Load balancing cluster
Answer: A
NEW QUESTION # 44
Your customer reports mat an external FC boot volume for Windows server is visible four times in the Disk Management 1 online and 3 offline.
What should you do to resolve this issue?
- A. Disable deduplication for this volume at the array level
- B. Install and configure MPIO on me Windows system
- C. Remove the offline disks using Windows Disk Management
- D. Remove the offline disks using array management tools
Answer: B
NEW QUESTION # 45
Which statement about manual orchestration during the firmware update is true?
- A. It provides the ability to install an older firmware version than currently Installed In the interconnect
- B. It allows all the interconnect modules to be activated manually at the same time.
- C. It provides an ability to select and update one side of the Interconnect topology at a time
- D. It is supported only for logical enclosures with at least three frames
Answer: C
NEW QUESTION # 46
Your customer wants to compare HPE Superdome Flex with HPE Superdome Flex 280.
Which statement about these two systems is true?
- A. Only HPE Superdome Flex 280 can support multiple nPars
- B. Only HPE Superdome Flex supports HPE Persistent Memory
- C. Only HPE Superdome Rex 280 can be managed using HPE OneView
- D. Only HPE Superdome Flex supports 32 sockets and 48TB of memory
Answer: C
NEW QUESTION # 47
Your customer plans to add four HPE Synergy frames to an existing management ring Ail installed frames are equipped with two 2-port FLM modules, while new frames will be equipped with 4-port FLM modules.
Which statement about mixing different FLM modules is true?
- A. Mixing different FLM modules is allowed if all of them have the same firmware version
- B. A management ring with mixed FLM modules cannot have more than 12 frames
- C. Existing 2-port FLM modules must be replaced with 4-port FLM modules
- D. A management ring can contain mixed frame link module configurations
Answer: B
NEW QUESTION # 48
After deploying HPE Superdome Flex 280 you need to check Core Analysis Engine (CAE) Log.
Click the appropriate section in the HPE Superdome Flex 280 management interface that will allow you to complete this task.
Answer:
Explanation:
NEW QUESTION # 49
Which statement about an HPE Oneview support dump is true?
- A. Support dump can be created if HPE Virtual Connect modules are installed in the frame
- B. Appliance support dump by default contains a logical enclosure support dump
- C. Preview support dump is available only when creating an appliance support dump
- D. Support dump is a binary file that can be opened only in a dedicated application
Answer: D
NEW QUESTION # 50
......
HP HPE0-S59 (HPE Compute Solutions) Certification Exam is a globally recognized certification exam that tests your knowledge and skills in designing, implementing, and managing HPE compute solutions. HPE0-S59 exam is designed for IT professionals who work in a variety of roles, including solution architects, system administrators, and technical consultants.
HPE0-S59 Certification Overview Latest HPE0-S59 PDF Dumps: https://certblaster.prep4away.com/HP-certification/braindumps.HPE0-S59.ete.file.html